Carbon oxides Nitrogen oxides (NOx) Hafnium oxide Combustible.
Pay attention to flashback.
Vapors are heavier than air and may spread along floors. May not get in touch with: Water
Development of hazardous combustion gases or vapours possible in the event of fire. Forms explosive mixtures with air at ambient temperatures.
In the event of fire, wear self-contained breathing apparatus.
Remove container from danger zone and cool with water. Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system.
Advice for non-emergency personnel: Do not breathe vapors, aerosols. Avoid substance contact. Ensure adequate ventilation. Keep away from heat and sources of ignition.
Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8.
Do not let product enter drains. Risk of explosion.
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up with liquid-absorbent material (e.g. Chemizorb? ). Dispose of properly. Clean up affected area.
For disposal see section 13.
Keep workplace dry. Do not allow product to come into contact with water.
Keep away from open flames, hot surfaces and sources of ignition.Take precautionary measures against static discharge.
Change contaminated clothing. Wash hands after working with substance. For precautions see section 2.2.
Tightly closed. Keep away from heat and sources of ignition. Never allow product to get in contact with water during storage.
Handle and store under inert gas.
Storage class (TRGS 510): 4.3: Hazardous materials, which set free flammable gases upon contact with water
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Safety glasses
required
Flame retardant antistatic protective clothing.
required when vapours/aerosols are generated.
Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system.
Recommended Filter type: Filter type ABEK
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer.
These measures have to be properly documented.
Do not let product enter drains. Risk of explosion.
No data available
Vapors may form explosive mixture with air.
sensitive to moisture
No data available
Do not allow water to enter container because of violent reaction. Warming.
Moisture.
Strong oxidizing agents, Water, Oxygen
In the event of fire: see section 5
No data available
No data available
No data available
No data available
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
No data available
See www.retrologistik.com for processes regarding the return of chemicals and containers, or contact us there if you have further questions.
ADR/RID: 3398 IMDG: 3398 IATA: 3398
ADR/RID: ORGANOMETALLIC SUBSTANCE, LIQUID, WATER-REACTIVE
(Tetrakis(ethylmethylamido)hafnium(IV))
IMDG: ORGANOMETALLIC SUBSTANCE, LIQUID, WATER-REACTIVE
(Tetrakis(ethylmethylamido)hafnium(IV))
IATA: Organometallic substance, liquid, water-reactive (Tetrakis(ethylmethylamido)hafnium(IV))
14.3 | Passenger Aircraft: Not permitted for transport Transport hazard class(es) | |
| ADR/RID: 4.3 IMDG: 4.3 | IATA: 4.3 |
14.4 | Packaging group ADR/RID: I IMDG: I | IATA: I |
14.5 | Environmental hazards ADR/RID: no IMDG Marine pollutant: no | IATA: no |
14.6 | Special precautions for user No data available | |
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.