Carbon oxides, Nitrogen oxides (NOx)
Wear self-contained breathing apparatus for firefighting if necessary.
No data available
HEALTH | 3 | Short exposure could cause serious temporary or moderate residual injury (e.g. liquid hydrogen, sulfuric acid, calcium hypochlorite, hexafluorosilicic acid) | |
FIRE | 0 | Materials that will not burn under typical fire conditions, including intrinsically noncombustible materials such as concrete, stone, and sand. Materials that will not burn in air when exposed to a temperature of 820 °C (1,500 °F) for a period of 5 minutes.(e.g. Carbon tetrachloride) | |
REACT | 0 | Normally stable, even under fire exposure conditions, and is not reactive with water (e.g. helium,N2) | |
SPEC. HAZ. |
For personal protection see section 8.
Do not let product enter drains.
Soak up with inert absorbent material and dispose of as hazardous waste. Keep in suitable, closed containers for disposal.
For disposal see section 13.
Avoid contact with skin and eyes. Avoid inhalation of vapour or mist. For precautions see section 2.2.
Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Store under inert gas. Sensitive to carbon dioxide
Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.
Impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Where risk assessment shows air-purifying respirators are appropriate use a full- face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Do not let product enter drains.
No data available
No data available
Stable under recommended storage conditions.
No data available
No data available
acids, Acid chlorides, Acid anhydrides, Oxidizing agents, Chloroformates
Hazardous decomposition products formed under fire conditions. - Carbon oxides, Nitrogen oxides (NOx)
Other decomposition products - No data available In the event of fire: see section 5
No data available
No data available
No data available
No data available
This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
No data available
Offer surplus and non-recyclable solutions to a licensed disposal company.
Dispose of as unused product.
ADR/RID: - IMDG: - IATA: -
ADR/RID: - IMDG: - IATA: -
ADR/RID: - IMDG: - IATA: -
ADR/RID: no IMDG Marine pollutant: no IATA: no
No data available
【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple
【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp
【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/
【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en
【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg
【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp
【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm
【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/
【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home
【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/
The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.