成人免费xx,国产又黄又湿又刺激不卡网站,成人性视频app菠萝网站,色天天天天

Chemical Safety Data Sheet MSDS / SDS

P-TOLYL CHLOROFORMATE

Revision Date:2023-11-29Revision Number:1

SECTION 1: Identification of the substance/mixture and of the company/undertaking

Product identifier

  • Product name: P-TOLYL CHLOROFORMATE
  • CBnumber: CB7422520
  • CAS: 937-62-2
  • EINECS Number: 213-332-8
  • Synonyms: p-tolyl carbonochloridate,P-TOLYL CHLOROFORMATE

Relevant identified uses of the substance or mixture and uses advised against

  • Relevant identified uses: For R&D use only. Not for medicinal, household or other use.
  • Uses advised against: none

Company Identification

  • Company: Chemicalbook
  • Address: Building 1, Huihuang International, Shangdi 10th Street, Haidian District, Beijing
  • Telephone: 400-158-6606

SECTION 2: Hazards identification

GHS Label elements, including precautionary statements

  • Symbol(GHS)
  • Signal wordDanger
Precautionary statements
P310 Immediately call a POISON CENTER or doctor/physician.
P305+P351+P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continuerinsing.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P261 Avoid breathing dust/fume/gas/mist/vapours/spray.
Hazard statements
H331 Toxic if inhaled
H314 Causes severe skin burns and eye damage
H311 Toxic in contact with skin
H301 Toxic if swalloed

SECTION 3: Composition/information on ingredients

Substance

  • Product name: P-TOLYL CHLOROFORMATE
  • Synonyms: p-tolyl carbonochloridate,P-TOLYL CHLOROFORMATE
  • CAS: 937-62-2
  • EC number: 213-332-8
  • MF: C8H7ClO2
  • MW: 170.59

SECTION 4: First aid measures

Description of first aid measures

General advice
Consult a physician. Show this material safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Take off contaminated clothing and shoes immediately. Wash off with soap and plenty of water. Take victim immediately to hospital. Consult a physician.
In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed
Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

Most important symptoms and effects, both acute and delayed

The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11

Indication of any immediate medical attention and special treatment needed

No data available

SECTION 5: Firefighting measures

Extinguishing media

Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Unsuitable extinguishing media
Do NOT use water jet.

Special hazards arising from the substance or mixture

Carbon oxides Hydrogen chloride gas Combustible.

Advice for firefighters

Wear self-contained breathing apparatus for firefighting if necessary.

Further information

Use water spray to cool unopened containers.

SECTION 6: Accidental release measures

Personal precautions, protective equipment and emergency procedures

Wear respiratory protection. Avoid breathing vapors, mist or gas. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safe areas. Beware of vapors accumulating to form explosive concentrations. Vapors can accumulate in low areas.

For personal protection see section 8.

Environmental precautions

Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

Methods and materials for containment and cleaning up

Contain spillage, and then collect with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see section 13). Keep in suitable, closed containers for disposal.

Reference to other sections

For disposal see section 13.

SECTION 7: Handling and storage

Precautions for safe handling

Advice on safe handling

Avoid contact with skin and eyes. Avoid inhalation of vapor or mist.

Advice on protection against fire and explosion

Keep away from sources of ignition - No smoking.Take measures to prevent the build up of electrostatic charge.

Hygiene measures

Avoid contact with skin, eyes and clothing. Wash hands before breaks and immediately after handling the product.

For precautions see section 2.2.

Conditions for safe storage, including any incompatibilities

Storage conditions

Keep container tightly closed in a dry and well-ventilated place. Containers which are

opened must be carefully resealed and kept upright to prevent leakage. Store in cool place.

Storage stability

Recommended storage temperature 2 - 8 °C

Vent periodically. Handle and open container with care. Moisture sensitive.

Specific end use(s)

Apart from the uses mentioned in section 1.2 no other specific uses are stipulated

SECTION 8: Exposure controls/personal protection

control parameter

Hazard composition and occupational exposure limits
Does not contain substances with occupational exposure limits.

Exposure controls

Personal protective equipment
Eye/face protection

Tightly fitting safety goggles. Faceshield (8-inch minimum). Use equipment for eye

protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).

Skin protection

Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.

The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it.

Body Protection

Complete suit protecting against chemicals, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.

Respiratory protection

Where risk assessment shows air-purifying respirators are appropriate use a full- face respirator with multi-purpose combination (US) or type ABEK (EN 14387) respirator cartridges as a backup to engineering controls. If the respirator is the sole means of protection, use a full-face supplied air respirator. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).

Control of environmental exposure

Prevent further leakage or spillage if safe to do so. Do not let product enter drains.

SECTION 9: Physical and chemical properties

Information on basic physicochemical properties

  • Appearancecolorless liquid
  • OdourNo data available
  • Odour ThresholdNo data available
  • pHNo data available
  • Melting point/freezing pointNo data available
  • Initial boiling point and boiling range 99,5 °C at 27 hPa - lit.
  • Flash point86 °C - closed cup
  • Evaporation rateNo data available
  • Flammability (solid, gas)No data available
  • Upper/lower flammability or explosive limitsNo data available
  • Vapour pressure No data available
  • Vapour density No data available
  • Relative densityNo data available
  • Water solubilityNo data available
  • Partition coefficient: n-octanol/waterNo data available
  • Autoignition temperatureNo data available
  • Decomposition temperatureNo data available
  • ViscosityViscosity, kinematic: No data available Viscosity, dynamic: No data available
  • Explosive propertiesNo data available
  • Oxidizing propertiesNo data available

Other safety information

No data available

SECTION 10: Stability and reactivity

Reactivity

No data available

Chemical stability

Stable under recommended storage conditions.

Possibility of hazardous reactions

No data available

Conditions to avoid

Heat, flames and sparks.

Incompatible materials

Strong bases, Strong oxidizing agents

Hazardous decomposition products

In the event of fire: see section 5

SECTION 11: Toxicological information

Information on toxicological effects

Acute toxicity
No data available
LC50 Inhalation - 4 h - 3 mg/l (Acute toxicity estimate) LD50 Dermal - 300 mg/kg
Skin corrosion/irritation
No data available
Serious eye damage/eye irritation
No data available
Respiratory or skin sensitization
No data available
Germ cell mutagenicity
No data available
Carcinogenicity
IARC: No ingredient of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity
No data available
Specific target organ toxicity - single exposure
No data available
Specific target organ toxicity - repeated exposure
No data available
Aspiration hazard
No data available

SECTION 12: Ecological information

Toxicity

No data available

Persistence and degradability

No data available

Bioaccumulative potential

No data available

Mobility in soil

No data available

Results of PBT and vPvB assessment

This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

Other adverse effects

No data available

SECTION 13: Disposal considerations

Waste treatment methods

Product

Offer surplus and non-recyclable solutions to a licensed disposal company. Waste material must be disposed of in accordance with the Directive on waste 2008/98/EC as well as other national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself.

Contaminated packaging

Dispose of as unused product.

SECTION 14: Transport information

UN number

ADR/RID: 3277 IMDG: 3277 IATA: 3277

UN proper shipping name

ADR/RID: CHLOROFORMATES, TOXIC, CORROSIVE, N.O.S. (p-Tolyl chloroformate) IMDG: CHLOROFORMATES, TOXIC, CORROSIVE, N.O.S. (p-Tolyl chloroformate)

IATA: Chloroformates, toxic, corrosive, n.o.s. (p-Tolyl chloroformate)

Transport hazard class(es)

ADR/RID: 6.1 (8) IMDG: 6.1 (8) IATA: 6.1 (8)

Packaging group

ADR/RID: II IMDG: II IATA: II

Environmental hazards

ADR/RID: no IMDG Marine pollutant: no IATA: no

Special precautions for user

No data available

SECTION 15: Regulatory information

Safety, health and environmental regulations/legislation specific for the substance or mixture

Regulations on the Safety Management of Hazardous Chemicals
China Catalog of Hazardous chemicals 2015:Not Listed. website: https://www.mem.gov.cn/
Measures for Environmental Management of New Chemical Substances
Vietnam National Chemical Inventory:Listed. website: https://chemicaldata.gov.vn/
European Inventory of Existing Commercial Chemical Substances (EINECS):Listed. website: https://echa.europa.eu/
EC Inventory:Listed.
United States Toxic Substances Control Act (TSCA) Inventory:Not Listed. website: https://www.epa.gov/
Philippines Inventory of Chemicals and Chemical Substances (PICCS):Not Listed. website: https://emb.gov.ph/
New Zealand Inventory of Chemicals (NZIoC):Not Listed. website: https://www.epa.govt.nz/
Korea Existing Chemicals List (KECL):Not Listed. website: http://ncis.nier.go.kr
Chinese Chemical Inventory of Existing Chemical Substances (China IECSC):Not Listed. website: https://www.mee.gov.cn/

SECTION 16: Other information

Abbreviations and acronyms

  • ADR: European Agreement concerning the International Carriage of Dangerous Goods by Road
  • CAS: Chemical Abstracts Service
  • EC50: Effective Concentration 50%
  • IATA: International Air Transportation Association
  • IMDG: International Maritime Dangerous Goods
  • LC50: Lethal Concentration 50%
  • LD50: Lethal Dose 50%
  • RID: Regulation concerning the International Carriage of Dangerous Goods by Rail
  • STEL: Short term exposure limit
  • TWA: Time Weighted Average

References

【1】CAMEO Chemicals, website: http://cameochemicals.noaa.gov/search/simple

【2】ChemIDplus, website: http://chem.sis.nlm.nih.gov/chemidplus/chemidlite.jsp

【3】ECHA - European Chemicals Agency, website: https://echa.europa.eu/

【4】eChemPortal - The Global Portal to Information on Chemical Substances by OECD, website: http://www.echemportal.org/echemportal/index?pageID=0&request_locale=en

【5】ERG - Emergency Response Guidebook by U.S. Department of Transportation, website: http://www.phmsa.dot.gov/hazmat/library/erg

【6】Germany GESTIS-database on hazard substance, website: http://www.dguv.de/ifa/gestis/gestis-stoffdatenbank/index-2.jsp

【7】HSDB - Hazardous Substances Data Bank, website: https://toxnet.nlm.nih.gov/newtoxnet/hsdb.htm

【8】IARC - International Agency for Research on Cancer, website: http://www.iarc.fr/

【9】IPCS - The International Chemical Safety Cards (ICSC), website: http://www.ilo.org/dyn/icsc/showcard.home

【10】Sigma-Aldrich, website: https://www.sigmaaldrich.com/

Disclaimer:

The information in this MSDS is only applicable to the specified product, unless otherwise specified, it is not applicable to the mixture of this product and other substances. This MSDS only provides information on the safety of the product for those who have received the appropriate professional training for the user of the product. Users of this MSDS must make independent judgments on the applicability of this SDS. The authors of this MSDS will not be held responsible for any harm caused by the use of this MSDS.

Recommended Products
P-TOLYL CHLOROTHIONOFORMATE SDS 4-METHOXYCARBONYLPHENYL CHLOROFORMATE SDS P-TOLYL CHLOROFORMATE SDS p-tert-butylphenyl chloroformate SDS