There will be a HazMat fee per item when shipping a dangerous goods. The HazMat fee will be charged to your UPS/DHL/FedEx collect account or added to the invoice unless the package is shipped via Ground service. Ship by air in Excepted Quantity (each bottle), which is up to 1g/1mL for class 6.1 packing group I or II, and up to 25g/25ml for all other HazMat items.
Type | HazMat fee for 500 gram (Estimated) |
Excepted Quantity | USD 0.00 |
Limited Quantity | USD 15-60 |
Inaccessible (Haz class 6.1), Domestic | USD 80+ |
Inaccessible (Haz class 6.1), International | USD 150+ |
Accessible (Haz class 3, 4, 5 or 8), Domestic | USD 100+ |
Accessible (Haz class 3, 4, 5 or 8), International | USD 200+ |
Purity | Size | Price | VIP Price | USA Stock *0-1 Day | Global Stock *5-7 Days | Quantity | ||||||
{[ item.p_purity ]} | {[ item.pr_size ]} | Inquiry |
{[ getRatePrice(item.pr_usd, 1,1,item.pr_is_large_size_no_price) ]} {[ getRatePrice(item.pr_usd,item.pr_rate,1,item.pr_is_large_size_no_price) ]} |
{[ getRatePrice(item.pr_usd, 1,1,item.pr_is_large_size_no_price) ]} | Inquiry {[ getRatePrice(item.pr_usd,item.pr_rate,item.mem_rate,item.pr_is_large_size_no_price) ]} {[ getRatePrice(item.pr_usd,1,item.mem_rate,item.pr_is_large_size_no_price) ]} | {[ item.pr_usastock ]} | in stock Inquiry - | {[ item.pr_chinastock ]} | {[ item.pr_remark ]} in stock Inquiry - | Login | Inquiry |
Please Login or Create an Account to: See VIP prices and availability
CAS No. : | 1120-48-5 | MDL No. : | MFCD00009557 |
Formula : | C16H35N | Boiling Point : | No data available |
Linear Structure Formula : | HN((CH2)7CH3)2 | InChI Key : | LAWOZCWGWDVVSG-UHFFFAOYSA-N |
M.W : | 241.46 | Pubchem ID : | 3094 |
Synonyms : |
|
Signal Word: | Danger | Class: | 8 |
Precautionary Statements: | P264-P270-P273-P280-P301+P312+P330-P301+P330+P331-P303+P361+P353-P304+P340+P310-P305+P351+P338+P310-P363-P391-P405-P501 | UN#: | 2735 |
Hazard Statements: | H302-H314-H410 | Packing Group: | Ⅲ |
GHS Pictogram: |
* All experimental methods are cited from the reference, please refer to the original source for details. We do not guarantee the accuracy of the content in the reference.
Yield | Reaction Conditions | Operation in experiment |
---|---|---|
81%; 18% | With platinum-nickel nanoclusters on activated carbon; hydrogen; at 180℃; under 760.051 Torr;Flow reactor; | General procedure: The reactions were performed in a flow-through reactor at atmospheric pressure and temperature 160-230. The reduced humid catalyst was loaded in the reactor between the glass layers of the nozzle and dried in a hydrogen stream at 120 prior to the reaction. The laboratory-grade reaction was a 12Kh18N10T steel tube (inner diameter 9 mm) put in an electric oven (heating zone height 50 mm). Temperature in the reactor was measured using a thermocouple. Hydrogen feed was adjusted using a GV-7 hydrogen generator. The feeding rate of the starting amines was 0.9 and 3.6 L kgcat-1 h-1 and that of hydrogen was 0.5 L h-1 gcat-1 at atmospheric pressure. |
Yield | Reaction Conditions | Operation in experiment |
---|---|---|
56%Chromat.; 18%Chromat.; 10%Chromat.; 12%Chromat. | With platinum-doped magnesium oxide; sodium hydroxide; at 150℃; under 750.075 Torr; for 36h;Inert atmosphere; Autoclave; | General procedure: After the reduction under a flow of H2 at 300C for 0.5h, we carried out catalytic tests without exposing the catalyst to air as follows. Methanol (30mmol) was injected to the reduced catalyst inside the glass tube through a septum inlet, thus the catalyst was covered with a layer of methanol to restrict it from air exposure. After removal of the septum under air, amine (1mmol), solid NaOH (1mmol), n-dodecane (0.25mmol) and a magnetic stirrer bar were placed in the tube. The tube was inserted into a stainless-steel autoclave (28cm3) and purged with N2 gas. Finally, the resulting mixture was heated at 150C and stirred under 1barN2. For the model reaction of n-octylamine, the catalyst screening, optimization of reaction conditions, kinetic studies and control reactions, the conversion of n-octylamine and yields of products were determined by GC analyses, using n-dodecane as an internal standard by applying the GC sensitivity of the isolated or commercial products. For the substrate scope study, the products were isolated by column chromatography with silica gel 60 (spherical, 60-100mum, Kanto Chemical Co., Ltd.) using hexane/ethyl acetate or ethyl acetate/methanol as the eluting solvent. The yields of the isolated amine derivatives were determined and identified by 1H and 13C NMR and GC-MS methods. |
Yield | Reaction Conditions | Operation in experiment |
---|---|---|
62%Chromat.; 11%Chromat.; 5%Chromat. | With rhodium contaminated with carbon; sodium hydroxide; at 150℃; under 750.075 Torr; for 36h;Inert atmosphere; Autoclave; | General procedure: After the reduction under a flow of H2 at 300C for 0.5h, we carried out catalytic tests without exposing the catalyst to air as follows. Methanol (30mmol) was injected to the reduced catalyst inside the glass tube through a septum inlet, thus the catalyst was covered with a layer of methanol to restrict it from air exposure. After removal of the septum under air, amine (1mmol), solid NaOH (1mmol), n-dodecane (0.25mmol) and a magnetic stirrer bar were placed in the tube. The tube was inserted into a stainless-steel autoclave (28cm3) and purged with N2 gas. Finally, the resulting mixture was heated at 150C and stirred under 1barN2. For the model reaction of n-octylamine, the catalyst screening, optimization of reaction conditions, kinetic studies and control reactions, the conversion of n-octylamine and yields of products were determined by GC analyses, using n-dodecane as an internal standard by applying the GC sensitivity of the isolated or commercial products. For the substrate scope study, the products were isolated by column chromatography with silica gel 60 (spherical, 60-100mum, Kanto Chemical Co., Ltd.) using hexane/ethyl acetate or ethyl acetate/methanol as the eluting solvent. The yields of the isolated amine derivatives were determined and identified by 1H and 13C NMR and GC-MS methods. |
Yield | Reaction Conditions | Operation in experiment |
---|---|---|
55%Chromat.; 14%Chromat.; 6%Chromat.; 12%Chromat. | With iridium on carbon; sodium hydroxide; at 150℃; under 750.075 Torr; for 36h;Inert atmosphere; Autoclave; | General procedure: After the reduction under a flow of H2 at 300C for 0.5h, we carried out catalytic tests without exposing the catalyst to air as follows. Methanol (30mmol) was injected to the reduced catalyst inside the glass tube through a septum inlet, thus the catalyst was covered with a layer of methanol to restrict it from air exposure. After removal of the septum under air, amine (1mmol), solid NaOH (1mmol), n-dodecane (0.25mmol) and a magnetic stirrer bar were placed in the tube. The tube was inserted into a stainless-steel autoclave (28cm3) and purged with N2 gas. Finally, the resulting mixture was heated at 150C and stirred under 1barN2. For the model reaction of n-octylamine, the catalyst screening, optimization of reaction conditions, kinetic studies and control reactions, the conversion of n-octylamine and yields of products were determined by GC analyses, using n-dodecane as an internal standard by applying the GC sensitivity of the isolated or commercial products. For the substrate scope study, the products were isolated by column chromatography with silica gel 60 (spherical, 60-100mum, Kanto Chemical Co., Ltd.) using hexane/ethyl acetate or ethyl acetate/methanol as the eluting solvent. The yields of the isolated amine derivatives were determined and identified by 1H and 13C NMR and GC-MS methods. |
Yield | Reaction Conditions | Operation in experiment |
---|---|---|
8%Chromat.; 9%Chromat.; 22%Chromat. | With silica-supported platinum; sodium hydroxide; at 150℃; under 750.075 Torr; for 36h;Inert atmosphere; Autoclave; | General procedure: After the reduction under a flow of H2 at 300C for 0.5h, we carried out catalytic tests without exposing the catalyst to air as follows. Methanol (30mmol) was injected to the reduced catalyst inside the glass tube through a septum inlet, thus the catalyst was covered with a layer of methanol to restrict it from air exposure. After removal of the septum under air, amine (1mmol), solid NaOH (1mmol), n-dodecane (0.25mmol) and a magnetic stirrer bar were placed in the tube. The tube was inserted into a stainless-steel autoclave (28cm3) and purged with N2 gas. Finally, the resulting mixture was heated at 150C and stirred under 1barN2. For the model reaction of n-octylamine, the catalyst screening, optimization of reaction conditions, kinetic studies and control reactions, the conversion of n-octylamine and yields of products were determined by GC analyses, using n-dodecane as an internal standard by applying the GC sensitivity of the isolated or commercial products. For the substrate scope study, the products were isolated by column chromatography with silica gel 60 (spherical, 60-100mum, Kanto Chemical Co., Ltd.) using hexane/ethyl acetate or ethyl acetate/methanol as the eluting solvent. The yields of the isolated amine derivatives were determined and identified by 1H and 13C NMR and GC-MS methods. |
Yield | Reaction Conditions | Operation in experiment |
---|---|---|
7%Chromat.; 22%Chromat.; 9%Chromat.; 33%Chromat. | With sodium hydroxide; at 150℃; under 750.075 Torr; for 36h;Inert atmosphere; Autoclave; | General procedure: After the reduction under a flow of H2 at 300C for 0.5h, we carried out catalytic tests without exposing the catalyst to air as follows. Methanol (30mmol) was injected to the reduced catalyst inside the glass tube through a septum inlet, thus the catalyst was covered with a layer of methanol to restrict it from air exposure. After removal of the septum under air, amine (1mmol), solid NaOH (1mmol), n-dodecane (0.25mmol) and a magnetic stirrer bar were placed in the tube. The tube was inserted into a stainless-steel autoclave (28cm3) and purged with N2 gas. Finally, the resulting mixture was heated at 150C and stirred under 1barN2. For the model reaction of n-octylamine, the catalyst screening, optimization of reaction conditions, kinetic studies and control reactions, the conversion of n-octylamine and yields of products were determined by GC analyses, using n-dodecane as an internal standard by applying the GC sensitivity of the isolated or commercial products. For the substrate scope study, the products were isolated by column chromatography with silica gel 60 (spherical, 60-100mum, Kanto Chemical Co., Ltd.) using hexane/ethyl acetate or ethyl acetate/methanol as the eluting solvent. The yields of the isolated amine derivatives were determined and identified by 1H and 13C NMR and GC-MS methods. |